Series Home UPS This is technological advancement from Servotech that we have produced
sine wave home UPS and Inverter that works on the world most advanced
technology DSP (Digital Signal Processing. The main advantage is that
it has an Active Power Factor Control Topological Pulse Charger. This
creates minimum water loss and increasing the battery life immensely.
For those areas where power goes off frequently, the system has been
provided selectable charging as high as 15 amp. to give optimal
charging time for batteries. It can also charge the battery from 120V to
290 input.
Salient Features
- Provides pure sine wave output
- Instant switchover for the computer to run uninterrupted during power cuts
- Provides extra long back-up for computer
- Space saver-ideal for modern day households
- User friendly display
- Saves 40% electricity bill as compared to square wave inverter
- Incorporates smart overload sensing and short-circuit protection with auto reset
Technical Specifications
Models
|
600 VA-1400 VA
|
AC input range
|
120V-280V(Inv.Mode), 185V-265V(UPS Mode)
|
Frequency
|
50Hz +- 0.1%(Battery Mode)
|
AC output
|
240V +- 10%
|
Power Factor
|
0.75 PF in Battery Mode
|
Battery Low Beep
|
10.30V per battery
|
Battery Cutoff
|
9.80V per battery
|
Charging Cutoff
|
13.80 (*NC Mode), 14.20V (*HC Mode)
|
Charging float and trapper stage voltage
|
13.40 (*NC Mode), 13.70V (*HC Mode) |
Overload trip
|
With in 10 sec on 110% Load
|
Overload Reset
|
3 time Reset, in case the load is not reduced then shutdown permanently
|
Short circuit
|
More than 250% Load will be treated as short circuit
|
| Fuse blown |
In case main fuse blown, it will give beep and mains indicator will be blinking but inverter will not work on
mains as well as on battery. |
| Charging current |
7.50 Amp (*NC Mode) 10.00 Amp (*HC Mode) |
| Indication |
Main, inverter ON, Charging, charged, fuse blown, Overload, Low battery |
|