Series Digital Home UPS Digital Home UPS, traditionally there are two separate power back up
systems i.e. UPS systems for computers and inverters for other domestic
appliances. with the increasing number of households having a computer,
it become an absolute necessity to have a single product providing
power back-up to computers as well as other domestic appliances.
Servotech Delite can provide power back-up computer as wall as home appliances during power cut. This result in
- Cost saving as only one systems (Delite) is bought in live of two systems (Inverter and UPS)
- Longer backup for computer as compared to UPS
- Appliance friendly: The life of the appliances like TV and fridge
is increased as there is NO Time Gap (Start up delay between power cut
and resumption of back-up power.
- Save in space by locating one system instead of two.
- Uninterrupted watching of TV and DVD, Satellite, Set Top Box etc.
Salient Features
- Micro controller based
- Runs the personal computer and acts as power backs for the home
- Advance battery management software inbuilt for longer battery life
Application
- Fan
- Tubelight
- Computer
- Fax machine
Technical Specifications
Models
|
600 VA-1400 VA
|
AC input range
|
120V-280V(Inv.Mode), 185V-265V(UPS Mode)
|
Frequency
|
50Hz +- 0.1%(Battery Mode)
|
AC output
|
240V +- 10%
|
Power Factor
|
0.75 PF in Battery Mode
|
Battery Low Beep
|
10.30V per battery
|
Battery Cutoff
|
9.80V per battery
|
Charging Cutoff
|
13.80 (*NC Mode), 14.20V (*HC Mode)
|
Charging float and trapper stage voltage
|
13.40 (*NC Mode), 13.70V (*HC Mode) |
Overload trip
|
With in 10 sec on 110% Load
|
Overload Reset
|
3 time Reset, in case the load is not reduced then shutdown permanently
|
Short circuit
|
More than 250% Load will be treated as short circuit
|
Indication
|
Main, inverter ON, Charging, charged, fuse blown, Overload, Low battery
|
| Fuse blown |
In case main fuse blown, it will give beep and mains indicator will be blinking but inverter will not work on
mains as well as on battery.
|
Charging current
|
7.50 Amp (*NC Mode) 10.00 Amp (*HC Mode)
|
|